EV Charging & E-Mobility Solutions Catalogue

Full catalog, 28 pages — browse the index or scroll the page.

All catalogs Download original PDF
Catalog index

World Prime Services provides a broad portfolio of electric vehicle charging and e-mobility infrastructure for private vehicles, commercial fleets, buses, heavy-duty vehicles, highway networks, commercial developments, residential projects and industrial applications. The portfolio combines AC destination charging, compact DC fast charging, integrated high-power DC systems, advertising-display charging stations, multi-standard AC/DC configurations, split-type charging architectures, liquid-cooled ultra-fast charging systems, automated battery swapping solutions and smart charging management.

Carregador de veículo elétrico World Prime Services em uso, cenário urbano — render de produto brand-neutral

Portfolio Overview

Product Family Power / Architecture Primary Application
AC Chargers7 / 11 / 22 kWResidential, workplace, hospitality, retail, condominium and destination charging.
Compact DC Fast Chargers30 / 40 kWCommercial parking, dealerships, urban destinations and moderate-throughput fast charging.
High-Power DC Fast Chargers60–400 kWPublic charging, highway corridors, fleet hubs, industrial sites and high-turnover stations.
Advertising Display DC Chargers160 kW classPremium commercial sites with integrated large-format digital advertising display.
Multi-Standard AC/DC ChargersUp to 142 kW combined configurationsMixed vehicle populations requiring multiple DC and AC connector standards.
Split-Type Charging SystemsCentralized high-power architectureBus depots, logistics fleets, large charging hubs and high-utilization operations.
Liquid-Cooled Ultra-Fast Systems720 / 960 / 1200 / 1600 kW host platformsUltra-fast hubs, heavy-duty fleets and high-density charging infrastructure.
Battery Swapping SystemsAutomated swap architectureCommercial fleets and high-utilization mobility requiring rapid vehicle turnaround.

AC Chargers 7/11/22 kW

World Prime Services AC charging solutions are engineered for everyday charging environments where vehicles remain parked for extended periods. The range is suitable for residential, condominium, workplace, hotel, retail, office and destination charging projects.

AC Chargers 7/11/22 kW
World Prime Services AC charger — clean, brand-neutral product visualization.
Carregador AC instalado em residência, com veículo em recarga
AC charger installed in a residential setting.
  • Rated power options: 7 kW, 11 kW and 22 kW.
  • Mode 3 AC charging architecture.
  • Wall-mounted or pedestal / column-mounted installation options.
  • Type 2 connector configuration for international applications; alternative connector configurations may be specified by project.
  • RFID, application-based or intelligent start options depending on configuration.
  • OCPP network communication options for smart charging and operator integration.
  • Multiple electrical protection functions including over-voltage, over-current, leakage and short-circuit protection.
  • Outdoor-ready enclosure options for commercial and semi-public installations.

Technical Specifications

Rated Power7 kW / 11 kW / 22 kW
Charging ModeModo 3
Typical Input Voltage176–264 Vac for selected single-phase configuration; 400 Vac class for selected three-phase configurations
Connector TypeType 2 / IEC 62196; project-specific alternatives available
Cable Length5 m typical configuration
Residual Current DetectionAC 30 mA + DC 6 mA on applicable configurations
ProtectionOutput short circuit, output overcurrent, input overvoltage, input undervoltage, PWM abnormal protection
Ingress ProtectionIP55 class depending on configuration
Operating Temperature-30°C a +50°C
Altitude≤2000 m
InstallationWall-mounted or column / pedestal-mounted
Networking4G or Ethernet on networked configurations
Communication ProtocolOCPP 1.6J / 2.0 depending on software configuration

Galaxy Series — Compact DC Fast Charger

The Galaxy Series is a compact DC fast-charging platform designed for locations where space efficiency, low acoustic impact and reliable fast charging are important. Typical installations include commercial buildings, dealerships, urban parking facilities, hotels, service areas and fleet support points.

Galaxy Series — Compact DC Fast Charger
Compact DC fast charger product visualization.
Série Galaxy instalada em local comercial, com veículo em recarga
Galaxy Series in operation at a commercial site.
  • 30 kW and 40 kW rated power configurations.
  • Compact wall-mounted or column-mounted installation.
  • Mode 4 DC charging.
  • 7-inch touch-screen user interface on applicable configurations.
  • 4G and Ethernet networking.
  • Industrial communication interfaces may include RS485, RS232 and CAN.
  • RFID, plug-and-charge, password and QR-code charging options.
  • Time, power, cost, automatic full-charge and scheduled charging modes.

Technical Specifications

Rated Power30 kW / 40 kW
Charging ModeModo 4
Typical Input Voltage400 Vac ±10%
Acoustic Noise≤65 dB; lower level possible with optional soundproof treatment
Ingress ProtectionIP55
Altitude≤2000 m
Operating Temperature-30°C a +50°C
InstallationWall-mounted or column-mounted
Typical Wall-Mount DimensionsAprox. 1300 x 700 x 300mm
Typical Column-Mount DimensionsAprox. 650 x 380 x 190mm
Display7-inch touch screen
Networking4G / Ethernet
Communication ProtocolOCPP 1.6J / 2.0

Vision Plus Series — 160 kW Advertising Display DC Charger

The Vision Plus Series integrates high-power DC charging with a large digital advertising display, creating a combined charging, payment and communication platform for high-visibility commercial locations.

Vision Plus Series — 160 kW Advertising Display DC Charger
Advertising-display DC charger product visualization.
Série Vision Plus instalada em centro comercial, com veículo em recarga
Vision Plus Series in operation at a shopping mall.
  • 160 kW rated output power.
  • Dual CCS2 charging guns, with optional CCS1 or GB/T configurations.
  • 32-inch 1920 × 1080 advertising display.
  • High-brightness screen suitable for commercial visibility.
  • POS, card, password and QR-code charging / payment workflows.
  • Automatic power allocation during dual-gun operation.
  • 200–1000 Vdc output range for broad EV platform compatibility.
  • Integrated cabinet design with 4G or Ethernet connectivity.

Technical Specifications

Rated Capacity160 kW
Charging GunsDual CCS2; optional CCS1 / GB/T
Advertising Display32 polegadas, 1920 x 1080
Backlight BrightnessAprox. 1500 cd/m²
Charging MethodPOS, card, password and QR scanning
InstallationIntegrated floor-standing design
Networking4G ou Ethernet
Typical Input Voltage400 Vac ±10%
Input Frequency45–65 Hz
Power Factor≥99%
Output Voltage200–1000 Vdc
Output Current0–250 A
Operating Temperature-30°C a +50°C
Ingress ProtectionIP55

Starpath Series — 60–400 kW High-Power DC Fast Charger

The Starpath Series is a high-power integrated DC charging platform designed for public charging stations, highways, fleets, industrial sites, logistics facilities and demanding operating environments.

Starpath Series — 60–400 kW High-Power DC Fast Charger
High-power integrated DC fast charger product visualization.
Série Starpath instalada em área de descanso rodoviária, com veículo em recarga e caminhão ao fundo
Starpath Series in operation at a highway rest area.
  • Wide rated power range from approximately 60 kW to 400 kW.
  • Broad 200–1000 Vdc vehicle charging range.
  • Flexible power distribution to improve charger utilization and operating stability.
  • Multiple start methods including scheduled charging, QR code, card, password, VIN and POS depending on configuration.
  • Designed for challenging environments including industrial locations, mines, high-altitude applications and cold climates.
  • Comprehensive electrical and thermal protection architecture.

Technical Specifications

Rated Power60–400 kW
Typical Input Voltage400 Vac ±10%
Input Frequency45–65 Hz
Power Factor≥99%
THD≤5%
ProtectionOutput short circuit, output overvoltage, output undervoltage, input overvoltage, input undervoltage, phase-loss and overtemperature protection
Ingress ProtectionIP55
Altitude≤2000 m
Operating Temperature-30°C a +50°C
Typical Cabinet DimensionsApprox. 1750 × 850 × 650 mm; final dimensions depend on configuration
Display7-inch touch screen
Networking4G / Ethernet
Charging AccessRFID, password, QR code; optional VIN
Communication ProtocolOCPP 1.6J / 2.0

Omni Point Series — Multi-Standard AC/DC Charging Solution

The Omni Point Series is engineered for sites serving a mixed population of electric vehicles and plug-in hybrid vehicles. Multi-connector configurations combine DC and AC charging standards within a single integrated platform.

Omni Point Series — Multi-Standard AC/DC Charging Solution
Multi-standard AC/DC charging station product visualization.
Série Omni Point instalada em pátio ao anoitecer, com veículos em recarga
Omni Point Series in operation at a charging hub.
  • Support for CCS1 / CCS2, CHAdeMO and GB/T DC configurations depending on project.
  • Type 1 / Type 2 / GB/T AC support depending on configuration.
  • Three-gun architecture suitable for mixed vehicle populations.
  • RFID, password, QR, VIN and application-based charging options.
  • Anti-corrosion cabinet and outdoor-oriented construction.
  • Operating voltage capability up to 1000 Vdc on applicable DC outputs.

Technical Specifications

Rated PowerApprox. 142 kW combined configuration
Charging ModesModo 4 / Modo 3
DC OutputTypical 120 kW main DC output plus auxiliary DC configuration depending on model
AC OutputUp to 22 kW depending on configuration
Typical Input Voltage400 Vac ±10%
Input Frequency45–65 Hz
Power Factor≥99%
Ingress ProtectionIP55
Altitude≤2000 m
Operating TemperatureAprox. -30°C a +60°C
Typical DimensionsAprox. 1763 x 920 x 588mm
Display7-inch touch screen
Networking4G / Ethernet
Communication ProtocolOCPP 1.6J / 2.0

Aurora Series — Liquid-Cooled Ultra-Fast Charging System

The Aurora Series uses a centralized high-power host with multiple charging terminals, allowing dynamic power distribution across multiple vehicles. Liquid-cooled charging technology enables very high connector current while supporting dense, high-utilization charging hubs.

Aurora Series — Liquid-Cooled Ultra-Fast Charging System
Centralized liquid-cooled ultra-fast charging system visualization.
Sistema Aurora instalado em posto de recarga, com veículos em recarga ao entardecer
Aurora system in operation at a high-power charging hub.
  • Host power platforms: 420kW, 720 kW, 960 kW, 1200 kW and 1600 kW.
  • Dynamic DC power allocation to connected charging terminals.
  • Standard fast-charging and liquid-cooled ultra-fast terminal options.
  • Maximum connector current up to approximately 1200 A on selected liquid-cooled configurations.
  • 200–1000 Vdc charging range.
  • Real-time monitoring, OTA update capability and multiple authentication methods.

Technical Specifications

Host Power Options720 / 960 / 1200 / 1600 kW
AC Input3F + N + PE
Typical Input VoltageTrifásica 400 Vac ±10%
Input Frequency45–65 Hz
Power Factor≥99%
Networking4G ou Ethernet
Ingress ProtectionIP65 class on applicable configuration
Altitude≤2000 m
Operating TemperatureAprox. -40°C a +50°C
Charging ModeModo 4
Output Voltage200–1000 Vdc
Standard Connector PowerUp to approximately 250 kW per connector depending on configuration
Liquid-Cooled Connector CapabilityUltra-high-power output; selected configurations up to approximately 1200 A

Split-Type High-Power Charging Systems

Split-type charging architecture separates the centralized power conversion cabinet from the charging terminals. This approach is suited to large charging hubs where multiple vehicles must be charged simultaneously and where centralized power allocation improves site utilization.

Split-Type High-Power Charging Systems
Split-type centralized charging system visualization.
Sistema split instalado em posto de recarga ao entardecer, com veículos em recarga
Split-type system in operation at a charging hub.
  • Centralized power cabinet with multiple remote charging terminals.
  • Dynamic power distribution according to vehicle demand and connector availability.
  • Suitable for highway charging hubs, logistics depots, bus parking, commercial fleets and heavy-duty vehicles.
  • Supports scalable station layouts with multiple parking spaces.
  • Can reduce duplication of high-power components compared with fully independent charger cabinets.
  • Networked monitoring and intelligent charging management support high-utilization operation.

Technical Specifications

ArchitectureCentralized DC power host + multiple charging terminals
Typical Site Power240 kW to 600 kW+ depending on project; higher centralized systems available
Vehicle StandardsCCS1 / CCS2 / GB/T ou configuração específica do projeto
Charging ManagementDynamic power distribution
NetworkingEthernet / 4G, conforme configuração
User AccessRFID, QR, application, password, VIN and other options depending on configuration
Primary ApplicationsHighway, bus, logistics, fleet, heavy-duty and high-utilization charging

Automated Battery Swapping Solutions

World Prime Services battery swapping solutions are intended for high-utilization commercial mobility where minimizing vehicle downtime is critical. Automated swapping allows the vehicle battery pack to be exchanged rapidly while removed batteries are charged under controlled conditions.

Automated Battery Swapping Solutions
Automated battery swapping station visualization.
Estação de troca de bateria em operação, com caminhão sendo atendido
Battery swapping station in operation with a fleet vehicle.
  • Automated battery swapping process with target cycle times below approximately 180 seconds depending on vehicle and station configuration.
  • Centralized battery charging and management.
  • Controlled charging environment supporting battery maintenance and thermal management.
  • Unattended operation and cloud-based monitoring capability.
  • Intelligent scheduling of battery charging according to grid loading and operational demand.
  • Suitable for fleet operations requiring repeated daily energy replenishment and rapid turnaround.

Technical Specifications

System TypeAutomated battery swapping station
Typical Swap TimeWithin approximately 180 seconds depending on vehicle / battery interface
Operating ModelAutomated / unattended-capable
Battery ManagementCentralized charging, monitoring and maintenance
Energy SchedulingIntelligent charging schedule for peak-shaving and off-peak optimization
MonitoringCloud-based remote monitoring capability
Primary ApplicationsCommercial fleets, high-utilization mobility, selected taxi / logistics / dedicated vehicle platforms

Smart Charging, OCPP & Cloud Connectivity

Network-connected charging infrastructure can be integrated into centralized charging management systems for continuous data collection, equipment monitoring, user management, billing, alarms, preventive maintenance and operational analysis.

Smart Charging, OCPP & Cloud Connectivity
  • OCPP 1.6J and OCPP 2.0 compatibility depending on charger and software configuration.
  • Remote charger status monitoring and session management.
  • Charging voltage, current, temperature and energy monitoring.
  • Operator access, user authentication and configurable tariff management.
  • Fault alarms and preventive maintenance workflows.
  • Remote firmware and configuration updates where supported.
  • Integration with commercial charging operators, fleet management systems and energy-management platforms.

Technical Specifications

Network Interfaces4G / Ethernet; Wi-Fi or other interfaces on selected AC configurations
Charging AuthenticationRFID, QR code, password, mobile application, plug-and-charge and VIN options depending on product
Payment OptionsPOS, card and QR options on applicable commercial models
Charging ModesTime, power, cost, amount, auto-full and scheduled modes depending on charger
Remote FunctionsMonitoring, alarms, statistics, configuration and maintenance support
Communication ProtocolOCPP 1.6J / 2.0, conforme configuração

Application Scenarios

The World Prime Services charging portfolio can be configured for different dwell times, vehicle classes, site capacities and operating profiles. Charger selection should be based on available electrical capacity, target vehicle battery voltage, expected daily energy throughput, simultaneous charging demand, connector standards and future expansion.

Application Recommended Range Operating Profile
Residential / Condominium7–22 kW ACOvernight and long-dwell charging; wall or pedestal installation.
Workplace / Office7–22 kW AC / compact DCEmployee and visitor charging with access control and network management.
Shopping Mall / Retail22–240 kW+Destination and fast charging with commercial payment and optional advertising display.
Commercial Building30–160 kW+Fast charging for tenants, visitors and corporate fleets.
Highway Rest Area120–600 kW+High-throughput rapid charging with multiple connectors and split-type architecture.
Fleet Depot60–600 kW+Scheduled fleet charging, dynamic load distribution and centralized management.
Bus DepotHigh-power split-typeMultiple terminals, high daily energy throughput and managed depot charging.
Heavy-Duty / Logistics240 kW to MW-classHigh-power DC and liquid-cooled ultra-fast charging.
Industrial / MiningHigh-power DC / liquid-cooledRugged charging for industrial electric vehicles and machinery.
Battery Swap FleetAutomated swap stationRapid turnaround for dedicated high-utilization vehicle platforms.

Selection Guide & Engineering Considerations

Product Selection Guide

Project Requirement Recommended Product Family
Long parking duration / low daily energy7–22 kW AC Charger
Limited space with DC fast charging requirementGalaxy 30/40 kW Compact DC
General public fast chargingStarpath 60–180 kW class
High-throughput urban / highway chargingStarpath 180–400 kW class
Commercial site requiring digital advertisingVision Plus 160 kW
Mixed connector standards / AC + DC requirementsOmni Point multi-standard platform
Large depot with many simultaneous vehiclesSplit-type centralized charging system
Ultra-fast highway / heavy-duty hubAurora liquid-cooled 720–1600 kW host
Dedicated fleet with minimum turnaround timeAutomated battery swapping system

Engineering Considerations

  • Available utility service, transformer capacity and site maximum demand.
  • Target vehicle voltage range, battery capacity and maximum charging acceptance rate.
  • Expected number of charging sessions per day and required turnaround time.
  • Number of simultaneous charging spaces and diversity factor.
  • Required connector standards and regional vehicle compatibility.
  • Cable length, cable management and accessibility requirements.
  • Ambient temperature, altitude, rain, dust, corrosion and installation environment.
  • Network connectivity, OCPP backend, payment, authentication and operator requirements.
  • Load management, demand control, energy storage or renewable-energy integration where applicable.
  • Civil works, electrical distribution, protection, grounding and future expansion provisions.

Need a quote for this equipment?

Talk to our team and get a tailored proposal.

Talk to a specialist